AD83.70-W-6000-22A | AHE test of electrical system metering pump, temperature circuit breaker, control module open circuit |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Metering pump, Temperature-controlled cutout, Control unit –//– Internal resistance |
a | M16 |
b | Check fuse F6/A5, replace if necessary. fuse trips again Ignition: OFF Heater unit: OFF (Run-on phase must have ended). Disconnect plug connection on metering pump (M16). Carry out measurement directly on both connections (on front right vehicle longitudinal frame, follow fuel line if necessary). | 3050 Ω | Value > 30 kΩ: Replace metering pump (M16) (–//–) Value in order: Inspect plug on metering pump (M16) (corrosion) if necessary. 1.1 |
1.1 | Metering pump, Temperature-controlled cutout, Control unit –//– Resistance of complete electric circuit of metering pump (M16) |
C1 | Z14 |
C2 | Ignition: OFF Heater unit: OFF Re-connect plug connection on metering pump (M16). Disconnect plug connection C on control unit (Z14). Carry out measurement at both connections from plug sleeve housing C. | 3050 Ω | Value > 30 kΩ: Cable harness (–//–) to metering pump (M16) 1.2 Value in order: Open-circuit in temperature-controlled cutout, in control unit or possibly on one plug connection / cable harness to temperature-controlled cutout, if necessary 1.3 |
1.2 | Metering pump, Temperature-controlled cutout, Control unit –//– Cable harness to metering pump (M16) |
2/1 | FF38 |
2/2 | Ignition: OFF Heater unit: OFF Disconnect plug connection FF38 under electrical compartment. Carry out measurement at both connections from plug sleeve housing FF38. | 3050 Ω | Value > 30 kΩ: Check short cable harness on fuel metering pump (M16) and both cables from FF9 to FF38 (under electrical compartment). If no fault can be determined: Inspect plug connections on cable harness from electrical compartment (FF38) to metering pump (on front right vehicle longitudinal frame), replace cable set if necessary. Value in order: Inspect plug connections on cable harness from electrical compartment (FF38) to FF9 and to control unit (Z14), install new cable harness if necessary. |
1.3 | Metering pump, Temperature-controlled cutout, Control unit –//– Circuit Temperature-controlled cutout |
A4 | Z14 |
A5 | Ignition: OFF Heater unit: OFF Re-connect plug on metering pump (M16). Disconnect plug connection A on control unit. Carry out measurement at plug sleeve housing A. | Value > 30 kΩ: 1.6 Value < 5 Ω: 1.4 Possible loose contact: Re-connect all plug connections, switch on ignition, erase fault memory and switch on heater unit. Then tap / shake plugs while observing HHT display. Fault cause is located at point where fault code re-appears. 1.5 | |
1.4 | Metering pump, Temperature-controlled cutout, Control unit –//– Internal resistance Control unit |
C1 | Z14 |
A5 | Ignition: OFF Heater unit: OFF Disconnect plug connection A and C on control unit (Z14). Carry out measurement at plug A and C. | Value > 30 kΩ: Replace control unit (Z14). | |
1.5 | Metering pump, Temperature-controlled cutout, Control unit –//– Resistance |
| Z14 Z14 |
C1 C2 | Ignition: OFF Heater unit: OFF Disconnect plug C on control unit (Z14). Ignition: ON Carry out measurements at plug C to ground. | < 20 V | Cables |
1.6 | Metering pump, Temperature-controlled cutout, Control unit –//– Internal resistance Temperature controlled cutout |
a | X7 |
b | Ignition: OFF heater unit (take care not to disconnect coolant circulation), if necessary refer to Danger! Risk of injury and of scalding with high coolant temperature! Disconnect plug connection on heater unit. Carry out measurement directly on plug X7 AD83.70-W-2000-18A. | Value > 30 kΩ: Inspect plug X7 for corrosion. Replace temperature-controlled cutout complete with cable and plug X7 if necessary. Allow heater unit to cool down if necessary and collect draining coolant. Value < 5 Ω: Inspect plug on heater unit for corrosion, if no fault can be determined: 1.7 | |
1.7 | Metering pump, Temperature-controlled cutout, Control unit –//– Supply cable |
14/5 | G |
14/7 | Ignition: OFF Heater unit: OFF Re-connect plug connection on heater unit. Carry out measurement at plug housing behind air recirculation box. | Value > 30 kΩ: Inspect 14-pin plug on blower for corrosion. Replace cable harness to heater unit complete with molded connection plate if necessary. Value < 5 Ω: Plug connection / cable –//– Inspect cable harness from air recirculation box to control unit (Z14) if necessary: 1.8 | |
1.8 | Metering pump, Temperature-controlled cutout, Control unit –//– Supply cable |
14/5 | FF8 |
14/7 | Ignition: OFF Heater unit: OFF Re-connect 14-pin plug connection on blower. Carry out measurement at plug sleeve housing FF8 under electrical compartment. | Value > 30 kΩ: Plug connection / cable (–//–) from air recirculation box to electrical compartment. Value < 5 Ω: Plug connection / cable –//– Inspect cable harness from control unit to electrical compartment (FF8), fit new cable if necessary (use 1 mm2, blue). | |