ad8370w400002b

AHE fault code description fault code group 05

Typ ad · téma 83.70 · verze 0100 · 2003-06-16

Platí pro: MODEL 625.1 /2, 655, 656, 657, 658, 659 with CODE (H08) Hot water auxiliary heater D 5 W MODEL 650, 651, 652, 653, 654 with CODE (H08) Hot water auxiliary heater D 5 W

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 625 (modely 1**, 2**) · Řada 650 · Řada 651 · Řada 652 · Řada 653 · Řada 654 · Řada 655 · Řada 656 · Řada 657 · Řada 658 · Řada 659

EinPAS 39 Topení/větrání/chlazení › 39.25 Nezávislé topení/přídavné topení › 39.25.1 Základní informace — Řada 625 (modely 1**, 2**) · Řada 650 · Řada 651 · Řada 652 · Řada 653 · Řada 654 · Řada 655 · Řada 656 · Řada 657 · Řada 658 · Řada 659

AD83.70-W-4000-02B

AHE fault code description fault code group 05

Fault code

Remedy / repair measure

Check heater unit, fuel supply and combustion air supply:

Ignition: ON

Switch on heater unit again, repeat several times as necessary.

If heater has previously functioned normally:

- Determine fuel level in fuel tank (intake point of fuel line for heater unit is higher than for injection pump).

- Inspect fuel filter and fuel lines (leak-tightness, etc.), repair if necessary.

- Check shutoff function of metering pump (intake line to fuel tank may empty).

- Inspect glow plug visually (heavy build-up / spiral wound filament open-circuited).

If heavy exhaust gas deposit (soot) was present:

- Determine fuel level in fuel tank (intake point of fuel line for heater unit is higher than for injection pump).

- Inspect fuel filter and fuel lines (leak-tightness, etc.), repair if necessary.

- Check shutoff function of metering pump (intake line to fuel tank may empty).

- Inspect glow plug visually (heavy deposit/ open-circuit in spiral wound filament ).

- Inspect fuel line visually. If no kink or mechanical defect can be determined, remove on heater and check whether fuel is being delivered (possibly blocked).

- Inspect heater unit intake and exhaust channels to check they are free.

- Combustion air blower power may no longer be sufficient (runs loud, motor bearing squeaks).

- Remove heavy carbon deposits in heat exchanger and on exhaust pipe if necessary.

- If no faults can be determined, replace control unit (Z13) on trial.

Ignition: ON

Switch heater unit off then on again.

Fault code re-appears:

Check quantity of fuel (refer to Repair Instructions). If fuel quantity is in order, refer to remedy / repair measure for fault code .

Fault code appears:

Refer to remedy / repair measure for fault code .

Ignition: ON

Allow heater unit to cool down and re-start.

Fault code appears:

Refer to remedy / repair measure for fault code .

Fault codes , or re-appear:

- Check whether intake and exhaust channels are free.

- Check blower speed (refer to Repair Instructions).

- Check fuel quantity (refer to Repair Instructions).

If another fault code appears:

Carry out appropriate test steps.

If no more fault codes appear, check whether heater fuel supply takes place without air entering (check fuel lines for leak-tightness, fuel filter for dirt).