AHE notes on flame monitor signal operational check using actual values
Typ ad · téma 83.70 · verze 0100 · 2003-06-16
Platí pro: MODEL 625.1 /2, 655, 656, 657, 658, 659 with CODE (H27) Hot water auxiliary heater DW 80 MODEL 650, 651, 652, 653, 654 with CODE (H27) Hot water auxiliary heater DW 80
Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.
AHE notes on flame monitor signal operational check using actual values
Faults in combustion can be detected through monitoring of flame monitor signal in conjunction with actual value 01:
Flame monitor must show "bright" after 60-80s after heater switched on. This state must be maintained unit coolant temperature of approx. 90 °C or unit shortly after switching off of heater (also at partial load).
If flame monitor sporadically goes dark during this phase: