ad8370w300601a

AHE notes on coolant temperature operational check using actual values

Typ ad · téma 83.70 · verze 0100 · 2003-06-16

Platí pro: MODEL 625.1 /2, 655, 656, 657, 658, 659 with CODE (H27) Hot water auxiliary heater DW 80 MODEL 650, 651, 652, 653, 654 with CODE (H27) Hot water auxiliary heater DW 80

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 625 (modely 1**, 2**) · Řada 650 · Řada 651 · Řada 652 · Řada 653 · Řada 654 · Řada 655 · Řada 656 · Řada 657 · Řada 658 · Řada 659

EinPAS 39 Topení/větrání/chlazení › 39.25 Nezávislé topení/přídavné topení › 39.25.1 Základní informace — Řada 625 (modely 1**, 2**) · Řada 650 · Řada 651 · Řada 652 · Řada 653 · Řada 654 · Řada 655 · Řada 656 · Řada 657 · Řada 658 · Řada 659

AD83.70-W-3006-01A

AHE notes on coolant temperature operational check using actual values

Coolant temperature is shown in °C. If applicable, compare with display instrument in vehicle. If value does not correspond check heater temperature sensor (at 25 °C 990–1010 Ω, at 80 °C resistance increases to approx. 1500 Ω).

After heater unit repair check following function processes:

1. During warm up phase (up to approx. 80 °C) heater unit runs on full load.

2. From 80 °C control unit switches heater to partial load (metering pump impulse slows down (once per second) and speed of combustion gas blower decreases).

a) With a lower heat requirement coolant temperature rises further (coolant circulation set to cab heating and vehicle engine running).

From approx. 90 °C control unit switches heater to stand-by (heater unit switched off and combustion air blower switched to run-on. Actual value 02: flame monitor becomes "dark"), temperature is therefore further monitored by control unit.

If temperature falls to approx. 75 °C control unit switches back to partial load.

b) With a higher heat requirement coolant temperature falls (coolant circulation set to engine heating). From approx.
70 °C control unit switches heater back to full load (actual value 02: flame monitor constantly "bright").