AD83.70-P-6001-05B | Stationary heater/heater booster test of electrical system fuel metering pump | Model 129 as of 01.06.97 and model 210 as of 01.01.96 with stationary heater Model 163 as of 01.09.01 with stationary heater Model 210 as of 01.09.96 and model 168,202 with heater booster |
| Test of | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 - / / -, |- -|+ | Wiring to fuel metering pump (Y23) Model 129 as of 01.06.97 and model 210 as of 01.01.96 with stationary heater Model 210 as of 01.09.96 and model 168, 202 with heater booster Model 163 as of 01.09.01 with stationary heater | Connec-tor D Y23 1 |
| Connec-tor D Y23 2 | Unplug connector at fuel metering pump Ignition: ON | Multimeter: Display no readout |
1.1 1.2 |
1.1 | Wiring from stationary heater/heater booster control module (A6n1) to fuel metering pump (Y23) Model 129 as of 01.06.97 Model 163 as of 01.09.01 | Connec-tor D Y23 1 |
| Connec-tor D Y23 2 | Unplug control cables connector (F): if stationary heater fitted if heater booster fitted | Multimeter: Display no readout |
Cable short circuit to positive Stationary heater/heater booster control module (A6n1) |
1.2 | Wiring from stationary heater/heater booster control module (A6n1) to fuel metering pump (Y23) | | Bridge connector of fuel metering pump Erase fault memory HHT/STAR DIAGNOSIS Actuate fuel metering pump Read out fault memory | Fault message HHT/STAR DIAGNOSIS: Fuel metering pump Y23 Fuel metering pump Y23 |
Fuel metering pump (Y23) Cables and connections | ||