ad8370p5001a

Stationary heater (STH) diagnosis, troubleshooting

Typ ad · téma 83.70 · verze 0102 · 2003-06-13

Platí pro: MODEL 129 as of 1.6.97 with CODE (228) stationary heater

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 129

AD83.70-P-5001A

Stationary heater (STH) diagnosis, troubleshooting

13.8.97

MODEL 129 as of 1.6.97 with CODE (228) stationary heater

Stationary heater (STH) diagnosis, advanced information

AD83.70-P-2001A

Stationary heater unit, location of components

GF83.70-P-0006-03B

Troubleshooting

Complaint

Possible cause

Note

Remedy

It is not possible to start the stationary heater unit

Undervoltage

Malfunction lock-out due to previous overheating

Stationary heater timer (N34)

Stationary heater/heater booster control module (A6n1)

Charge battery

See Hand-Held Tester (HHT)

AD83.70-P-6001-03A

Check all actual values with HHT

Malfunction shut-down at start of heater operation with heater unit run-on (approx. 120 seconds ) of combustion air blower (A6m2) and circulating pump (A6m1) without repeat start.

Glow pin (A6r2) in its flame monitor function

Stationary heater/heater booster control module (A6n1)

Check all actual values with HHT

Malfunction shut-down at start of heater operation with heater unit run-on (approx. 120 seconds) of combustion air blower (A6m2) and circulating pump (A6m1) after an unsuccessful repeat start initiated automatically.

Stationary heater fuel metering pump (Y23)

Combustion air blower (A6m2)

Glow pin (A6r2) in its flame monitor function

Stationary heater/heater booster control module (A6n1)

Check all actual values with HHT

Combustion starts during the preglow time

Remains of fuel in combustion chamber due to unsuccessful attempts at starting

Internal leakage in fuel metering pump (Y23)

Allow heater unit to operate for 10 minutes

AD83.70-P-7000-02A

Vehicle heater blower does not operate at a coolant temperature > 30°C

Blower motor (M2)

Actuation of air conditioning (automatic) control and operating system

AD83.70-P-6001-09A

AD83.70-P-6001-08A

Stationary heater/heater booster unit (A6) does not switch to full load operation despite a requirement for heat

Combustion air blower (A6m2)

Stationary heater fuel metering pump (Y23)

Stationary heater/heater booster control module (A6n1)

Check all actual values with HHT

Despite a requirement for heat, the stationary heater/heater booster unit (A6) goes into the combustion interval within approx. 10 minutes during trouble-free heater mode.

Coolant level or routing of coolant lines

Actuation of blower motor (M2)

Blower motor (M2)

Circulating pump (A6m1)

Stationary heater/heater booster control module (A6n1)

Check coolant level, if necessary replenish and/or bleed coolant circuit.

Check coolant lines for kinks and pinching

AD83.70-P-6001-08A

AD83.70-P-6001-09A

Check all actual values with HHT

Heat output too low

Setting of vehicle heater

Combustion air inlet on stationary heater/heater booster unit (A6)

Coolant level or routing of coolant lines

Heater circuit thermostat

Stationary heater/heater booster control module (A6n1)

Increase temperature setting

Check combustion air inlet for contamination and clean if necessary

Check coolant level and if necessary replenish and/or bleed coolant circuit.

Check coolant lines for kinks and pinching.

Check function

Check all actual values with HHT

Despite a reduced requirement for heat, stationary heater/heater booster unit (A6) is not switched to part load operation or to the combustion interval.

Stationary heater/heater booster control module (A6n1)

Check all actual values with HHT

Escape of combustion exhaust gases which are sooty or form dense smoke

Combustion air inlet at stationary heater/heater booster unit (A6)

Exhaust emissions value too high

Fuel delivery quantity

Combustion air blower (A6m2)

Stationary heater/heater booster control module (A6n1)

Check combustion air inlet for contamination and if necessary clean

Check and adjust exhaust emissions value with HHT

AD83.70-P-7000-01A

Check all actual values with HHT

Gray/white combustion exhaust gases (white smoke)

Exhaust emissions value too low

Check and adjust exhaust emissions value with HHT

Loss of coolant

Gray/white combustion exhaust gases (white smoke)

Exhaust gas odor extremely sweet

Stationary heater/heater booster unit (A6)

Check stationary heater/heater booster unit (A6) for external leaks and if necessary replace heater unit.

Loss of fuel or fuel odor

Fuel supply of stationary heater unit leaks

Localize leakage point, check fuel metering pump, fuel supply lines, connections and stationary heater unit for fuel leaks and if necessary seal leakage point or replace component

Heater operation cannot be terminated manually

Stationary heater timer (N34)

AD83.70-P-6001-03A

It is not possible to test the stationary heater components with the HHT

No communication between HHT and stationary heater/heater booster control module (A6n1)

Cables, cable connections

Voltage supply

Diagnostic cable

Check and if necessary replace

AD83.70-P-6001-01A

AD83.70-P-6001-02A

Odkazované dokumenty