P83.70-2167-06
"Thermo Top S" stationary heater
A Coupling, PTC-resistance flame monitor (A6r3)
1 Flame monitor brown
2 Flame monitor brown
B Coupling, circulating pump (A6m1)
1 Circulating pump black
2 Circulating pump brown
C Coupling, combustion air blower (A6m2)
1 Combustion air blower lilac
2 Combustion air blower brown
D Coupling, glow pin (A6r2)
1 Glow pin yellow
2 Glow pin yellow
E Coupling, current supply
1 Terminal 30 red/green
2 Ground brown
F Coupling, control lines
1 Input from stationary
heater timer (N34) black/red
2 Diagnostic output
(X11/4) lilac
5 STH microswitch
(S46/7) brown/white
6 Output for
stationary heater
fuel metering
pump (Y23) blue/red
3 Not assigned -
4 Output for
actuation of
blower motor
(M2) yellow/black
P83.70-0426-06
"Thermo Top C" stationary heater
A Not assigned
B Coupling, circulating pump (A6m1)
1 Circulating pump black
2 Circulating pump brown
C Coupling, combustion air blower (A6m2)
1 Combustion air blower lilac
2 Combustion air blower brown
D Coupling, glow pin (A6r2)
1 Glow pin yellow
2 Glow pin yellow
E Coupling, voltage supply
1 Terminal 30 red/green
2 Ground brown
F Coupling, control lines
1 Input from stationary heater timer (N34) black/red
2 Diagnostic output (X11/4) lilac
3 Not assigned -
4 Output for
actuation of blower
motor (M2) yellow/black
5 STH microswitch (S46/7) brown/white
6 Output for stationary
heater fuel metering
pump (Y23) blue/red