ad8370d3006c

Auxiliary heater (AHE) diagnosis operational check using actual values

Typ ad · téma 83.70 · verze 0100 · 2003-06-13

Platí pro: MODEL 901.###, 902.###, 903.###, 904.### ## as of 753731 as of 3.11.97 with CODE (H11) Warm air auxiliary heater Heater designation B3L-C compact, Heater designation D3L-C compact

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 901 · Řada 902 · Řada 903 · Řada 904

AD83.70-D-3006C

Auxiliary heater (AHE) diagnosis operational check using actual values

21.7.98

MODEL 901.###, 902.###, 903.###, 904.### ## as of 753731 as of 3.11.97 with CODE (H11) Warm air auxiliary heater
Heater designation B3L-C compact,
Heater designation D3L-C compact

Danger!

Risk of explosion due to fuel vapors, risk of poisoning from inhaling combustion gases and risk of injury from burns during or after heater operation

Do not start stationary heater/auxiliary heater with engine booster in confined spaces or while refueling. Allow heater to cool down after operation and wear safety gloves.

AS83.70-Z-0002-01A

Auxiliary heater (AHE) diagnosis, previous knowledge

AD83.70-D-2000D

Function check using actual values

Actual value no.

Actual value

Specified value

Operating voltage

> 10.5 V

Output

xx %

Actual value temperature

(interior temperature)

xx °C

AD83.70-D-2000-07B

Temperature specified value

(control range +10°C to + 30°C)

xx °C

Flame sensor resistance

x.xx kΩ

AD83.70-D-2000-07B

Switch on signal

Display: ON

Metering pump

Display: ON

Glow plug (glow plug glows)

Display: ON

Blower motor

Display: ON

Odkazované dokumenty