ad8050d6000a

Anti-theft alarm (ATA) test of electrical system

Typ ad · téma 80.50 · verze 0101 · 2003-06-13

Platí pro: MODEL 901, 902, 903, 904 with CODE (J67) Anti-theft alarm system

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 80 Centrální zamykání, komfortní ovládání, systémy oprávnění k jízdě › 80.50 Varovné zařízení proti vloupání a odcizení vozidla (EDW), ochrana vnitřního prostoru/ochrana proti odtažení — Řada 901 · Řada 902 · Řada 903 · Řada 904

AD80.50-D-6000A

Anti-theft alarm (ATA) test of electrical system

25.7.97

MODEL 901, 902, 903, 904 with CODE (J67) Anti-theft alarm system

Anti-theft alarm system (ATA) diagnosis previous knowledge

AD80.50-D-2000A

Battery voltage 11-14 V

Complete ATA system (all connectors connected)

Central locking and remote radio control (FFB) in order

Turn signal system in order

The cables, connectors and plug-in connections are taken into consideration during testing using the HHT, and may need to be separately re-tested for breaks, good contact and correct connection as per the relevant circuit diagram a fault is indicated.

Connect Hand-held Tester (HHT)

AD00.00-D-2000-03A

Testing

1

Anti-theft alarm system (ATA) testing of electrical system, control module

Voltage supply

AD80.50-D-6000-28A

2

Anti-theft alarm (ATA) test of electrical system, hood switch

AD80.50-D-6000-01A

3

Anti-theft alarm system (ATA) testing of electrical system, panic switch

AD80.50-D-6000-23A

4

Anti-theft alarm system (ATA) testing of electrical system, alarm signal horn

AD80.50-D-6000-03A

5

Anti-theft alarm system (ATA) testing of electrical system, turn signal alarm circuit

AD80.50-D-6000-19A

6

Anti-theft alarm system (ATA) testing of electrical system, trailer monitor

AD80.50-D-6000-30A

7

ATA testing of electrical system, door contact

With fault code 003

AD80.50-D-6000-39A

8

Anti-theft alarm system (ATA) testing of electrical system, tailgate alarm circuit

With fault code 004

AD80.50-D-6000-32A

9

Anti-theft alarm system (ATA) testing of electrical system, control module

With fault code 100

AD80.50-D-6000-28B

10

ATA testing of electrical system, connection to central locking system

With fault code 104

AD80.50-D-6000-40A

11

ATA testing of electrical system, connection to central locking system

With fault code 105

AD80.50-D-6000-40B

12

ATA testing of electrical system, lock switch

With fault code 109

AD80.50-D-6000-41A

13

ATA testing of electrical system, lock switch

With fault code 111

AD80.50-D-6000-41B

Odkazované dokumenty