AD80.35-P-6000-34A | Electric steering column locking, data buses, testing electrical system (RFL/RCL) |
| Scope of test | Measuring instrument/ | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Electric steering column locking (N26/5) Data buses –//– | N26/5 3 N26/5 4 |
| N73 4 (B) N73 5 (B) | Disconnect coupling (B) from N73 and coupling from N26/5 |
<1 Ω <1 Ω | Cables |
2.0 | Electric steering column locking (N26/5) Data buses – |
|
| N26/5 3 N26/5 4 | Disconnect coupling from N26/5 |
>20 kΩ >20 kΩ | Cables |
33.0 | Electric steering column locking (N26/5) Data buses + | N26/5 3 N26/5 4 |
|
+ + | Disconnect coupling from N26/5 |
>20 kΩ >20 kΩ | Cables |