AD80.35-D-6003-05A | Immobilizer indicator lamp, testing IMM electrical system |
| Scope of test | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Immobilizer indicator lamp Actuation (CAN) | | Ignition: ON Indicator lamp actuation OFF |
ON OFF | Cable Indicator lamp Instrument cluster Specification o.k.: Erase fault memory and carry out operational check | ||
1.1 | -//- (CAN) |
|
| A53 4 | Ignition: OFF Socket at WSP control unit disconnected (OM 601: additionally unplug connector (1) at preglow time relay) | <25 Ω | Cable Indicator lamp Instrument cluster |
1.2 | - (CAN) |
|
| A53 4 | Ignition: OFF Socket at WSP control unit and connector 2 (white) at instrument cluster disconnected (OM 601: additionally unplug connector (1) at preglow time relay) | >20 kΩ | Cable |
1.3 | + (CAN) |
|
| A53 4 | Socket at WSP control unit and connector 2 (white) at instrument cluster disconnected (OM 601: additionally unplug connector (1) at preglow time relay) Ignition: ON |
<1 V | Cable Further possibilities: WSP control unit |