AD80.35-D-6002-07B | RFL test of electrical system immobilizer malfunction indicator lamp | Engine 601, 602 |
| Scope of test | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Immobilizer indicator lamp Actuation (CAN) | | Ignition: ON Immobilizer indicator lamp ON OFF |
ON OFF | Wiring Indicator lamp Instrument cluster Specification OK: Erase fault memory and perform operational check | ||
1.1 | -//- (CAN) |
|
| A25.1 4 | Ignition: OFF Socket disconnected at RFL control module (Engine OM 601 and OM 602 with DFI control module, additionally unplug connector 1 at preglow time relay.) | <25 Ω | Wiring Indicator lamp Instrument cluster |
1.2 | - (CAN) |
|
| A25.1 4 | Ignition: OFF Socket at RFL control module and connector 2 (white) at instrument cluster disconnected (Engine OM 601 and OM 602 with DFI control module, additionally unplug connector 1 at preglow time relay.) | >20 kΩ | Wiring |
1.3 | + (CAN) |
|
| A25.1 4 | Socket at RFL control module and connector 2 (white) at instrument cluster disconnected (Engine OM 601 and OM 602 with DFI control module, additionally unplug connector 1 at preglow time relay.) (Engine OM 602 with DFI control module, additionally remove relay K45) Ignition: ON |
<1 V | Wiring Further possibilities: RFL control module |