ad8020d500101a

Troubleshooting chart, diagnosis, CL

Typ ad · téma 80.20 · verze 0100 · 2003-06-12

Platí pro: MODEL 901, 902, 903, 904 with CODE (FZ0) Zentralverriegelung mit Hauptschlüssel '

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 80 Centrální zamykání, komfortní ovládání, systémy oprávnění k jízdě › 80.20 Centrální zamykání, vnitřní centrální zamykání — Řada 901 · Řada 902 · Řada 903 · Řada 904

EinPAS 29 Oprávnění k jízdě / zabezpečovací systém › 29.16 Zamykání/odemykání › 29.16.1 Základní informace — Řada 901 · Řada 902 · Řada 903 · Řada 904

AD80.20-D-5001-01A

Troubleshooting chart, diagnosis, CL

Connect central locking tester to the connector in place of the CL control module.

Unlock vehicle mechanically.

Note

Doors not fitted are indicated by both LEDs (green and red) lighting up.

No

Yes

No

Yes

Test fuse F44 and replace if necessary. Test voltage supply of CL control module according to current wiring diagram.

Check whether the door which the central locking tester has indicated as faulty, is correctly closed.

If YES:

Test wiring, command switch, rotary tumbler switch and actuator motor of the relevant door, see "Test of electrical system".

Green LEDs of all doors fitted come on and

Red LEDs of all doors fitted do not come on.

Circuit 30 LED comes on?

Check whether the door which the central locking tester has indicated as faulty, is correctly closed.

If YES:

Test wiring, command switch, rotary tumbler switch and actuator motor of the relevant door, see "Test of electrical system".

No

Green LEDs of all doors fitted come on and

Red LEDs of all doors fitted do not come on.

Yes

Lock vehicle with pushbutton at central locking tester.

Unlock vehicle with pushbutton at central locking tester.

Green LEDs of all doors fitted come on and

Red LEDs of all doors fitted do not come on.

Check whether the door which the central locking tester has indicated as faulty, is correctly closed.

If YES:

Test wiring, command switch, rotary tumbler switch and actuator motor of the relevant door, see "Test of electrical system".

No

Operational check OK?

END

Replace door lock with actuator.

No

Yes

Replace CL control module and carry out operational check.

Yes