AD54.30-D-6000-17A | IC test of electrical system preglow and immobilizer indicator lamp |
| Scope of test | Measuring instrument/Test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Preglow and immobilizer (DAS) malfunction indicator lamp Cable and instrument cluster | 3 | | 1 | Coupling disconnected at preglow time-limit relay Coupling disconnected at radio remote operation control module Ignition: ON | Malfunction indicator lamp illuminates | Cable Malfunction indicator lamp Instrument cluster If in order: Preglow time-limit relay or radio remote operation control module |
1.1 | Function | 19 (2.1) | | 3 (1.5) | Instrument cluster removed Adapter connected with adapter cable Bridge to adapter cable | Malfunction indicator lamp illuminates | Malfunction indicator lamp Instrument cluster |