AD54.30-D-6000-16A | IC test of electrical system preglow indicator lamp |
| Scope of test | Measuring instrument/Test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Preglow indicator lamp Cable and instrument cluster | 3 | | 1 | Coupling disconnected at preglow time-limit relay Ignition: ON | Malfunction indicator lamp illuminates | Cable Malfunction indicator lamp Instrument cluster If in order: Preglow time relay |