AD54.30-D-6000-08A | IC test of electrical system fuel gage |
| Scope of test | Measuring instrument/Test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Fuel gage Cable and instrument cluster | 3 | | 2 | Ignition: OFF Coupling disconnected at fuel gage sensor Connect Ohm decade Ignition: ON Ohm decade 180 Ω 149 Ω 127 Ω 82 Ω 43 Ω 10 Ω Reserve indicator lamp illuminates at 180 Ω and 149 Ω |
Display: =̂ 0 =̂ Res. =̂ 1/4 =̂ 1/2 =̂ 3/4 =̂ 1 | Cable Instrument cluster |
1.1 | Fuel gage sensor (B3) Resistance | B3 | Ignition: OFF Coupling disconnected at fuel gage | 1844 Ω Empty 101 Ω Full | Fuel gage sensor (B3) | ||
1.2 | Cable | | | 6 (2.6) | Ignition: OFF Plug 2 disconnected from instrument cluster, plug housing open | 1844 Ω Empty 101 Ω Full | Cable |
1.3 | Fuel gage Function | 12 (1.7) 1 (1.4) | | 3 (1.5) 14 (2.6) | Instrument cluster removed Adapter connected with adapter cable Connect Ohm decade Ohm decade 180 Ω 149 Ω 127 Ω 82 Ω 43 Ω 10 Ω Reserve indicator lamp illuminates at 180 Ω and 149 Ω to adapter cable |
Display: =̂ 0 =̂ Res. =̂ 1/4 =̂ 1/2 =̂ 3/4 =̂ 1 | Instrument cluster |