AD07.61-P-6001-01A | Testing of electrical system for ME-SFI control module terminal 30 in ME-SFI ignition system |
| Scope of test | Tester/test connection | Operation/ Prerequisite: | Specified value | Possible cause/ Remedy | ||
1.0 | ME-SFI control module (N3/10) Voltage supply terminal 30 |
3 (3A) | N3/10 |
12 (4B) | Ignition: ON | 11-14 V | 1.1 1.2 |
1.1 | Ground cables |
N3/10 3 (3A) 7 (7A) 112 (8F) 119 (15F) |
|
X11/4 2 X11/4 2 X11/4 2 X11/4 2 | Ignition: ON On model 163, connect to 16-pin test coupling, socket 8. | 11-14 V | Cable Models 202/208/210: Electronics ground, right of component compartment (W16/6) Model 163: Ground (component compartment) (W16) Model 129: Ground (control module box/module box bracket) (W27) Model 463: Ground (right A pillar) (W29/2), ground (control module box/module box bracket) (W27) |
1.2 | Voltage supply terminal 30 |
X11/4 1 |
|
N3/10 12 (4B) | Ignition: ON On model 163, connect to 16-pin test coupling, socket 4. | 11-14 V | Cable Fuse and relay module, base module (K40, K40/4, N16/1 or F1) |