AD07.61-P-6000-04A | Testing of electrical system for ME-SFI fuel injection system hot film air mass sensor |
| Scope of test | Tester/test connection | Operation/ Prerequisite: | Specified value | Possible cause/ Remedy | ||
1.0 | Hot film mass air flow sensor (B2/5) Hot film signal |
104 | N3/10 |
103 (47E) | Ignition: ON Engine: idling Coolant temperature > 70° c | 0.9-1.1 V 1.3-1.7 V Increasing rpm, increasing voltage | 1.1 1.2 1.3 Cable Unmetered air B2/5 |
1.1 | Hot film mass air flow sensor (B2/5) Voltage supply 5 V | N3/10 104 (48E) |
|
B2/5 4 | Unplug coupling to hot film mass air flow sensor (B2/5) and check direct at socket 4 (brown/yellow) Ignition: ON |
4.7-5.2 V | Cable N3/10 |
1.2 | Ground lead for hot film air mass sensor (B2/5) |
B2/5 3 |
| N3/10 102 (46E) | Unplug coupling to hot film mass air flow sensor (B2/5) and check direct at socket 3 (brown) Ignition: ON |
4.7-5.2 V | Cable |
1.3 | Hot film mass air flow sensor (B2/5) Voltage supply 12 V | N3/10 104 (48E) |
|
B2/5 2 (2) | Unplug coupling to hot film mass air flow sensor (B2/5) and connect voltmeter plus to socket 2 (red/blue) Ignition: ON |
11-14 V | Cable Fuse and relay module, base module (K40/4, F1f11 or N16/1) |