Variable intake manifold switchover valve | ||
1A | Fault code ( Display on generic scan tool) | P2074 (-) |
1B | Engine 112, 113 as of 1/01 Fault code ( Display on generic scan tool) | P2074-[1] Short circuit to positive (-) P2074-[2] Short circuit to ground(-) P2074-[4] Line interruption (-) |
2 | Fault storage Activation of the engine diagnosis indicator lamp (EURO3/4) or CHECK ENGINE (MIL) malfunction indicator lamp | After expiry of test duration and fault No activation |
3 | Checking frequency | Continuous |
4 | Checked signal or status | Current/ voltage test at variable intake manifold switchover valve |
5 | Fault setting conditions Limit values Short circuit to ground Short circuit to positive Line interruption |
Voltage lower than 2.5 V Current higher than 4.2 A No voltage at variable intake manifold switchover valve Approx. 4 to 8 V at output of ME-SFI control unit under no load. |
6 | Check prerequisites | Battery voltage between 8 and 17 V |
7 | | Actuation of the variable intake manifold switchover valve is checked for to detect a cable breakage and short-circuit (to ground or battery voltage). A short circuit to ground and a line interruption will be detected when the output stages are locked, whilst a short circuit to the battery voltage will be detected when the output stages are conducting. The output stage is immediately no longer activated when a fault arises. |