ad0761p400071l

Electric suction fan, ME-SFI fault code description

Typ ad · téma 07.61 · verze 0102 · 2005-08-18

Platí pro: ENGINE 112.910 /911 /920 /921 /922 /940 /941 /942 /944 as of 1.6.00 ENGINE 112.912 /913 /914 /916 /917 /923 /943 /946 /947 /949 /953 /954 /955 /970 /972 /973 /975 ENGINE 113.940 /941 /942 /943 /960 as of 1.6.00 ENGINE 113.948 /961 /963 /964 /965 /966 /967 /968 /969 /971 ENGINE 112.945, 113.962 as of 1.11.00 in MODEL 463 ENGINE 137.970

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 07 Příprava směsi › 07.61 Systém vstřikování paliva a zapalování zážehového motoru ME — Řada 463

EinPAS 15 Motor › 15.25 Chladicí systém motoru › 15.25.1 Základní informace — Řada 463

Platí také pro motory/převodovky: 112 910, 112 911, 112 912, 112 913, 112 914, 112 916, 112 917, 112 920, 112 921, 112 922, 112 923, 112 940, 112 941, 112 942, 112 943, 112 944, 112 945, 112 946, 112 947, 112 949, 112 953, 112 954, 112 955, 112 970, 112 972, 112 973, 112 975, 113 940, 113 941, 113 942, 113 943, 113 948, 113 960, 113 961, 113 962, 113 963, 113 964, 113 965, 113 966, 113 967, 113 968, 113 969, 113 971, 137 970

AD07.61-P-4000-71L

Electric suction fan, ME-SFI fault code description

Electric suction fan, actuation

1

Fault code

( Display on generic scan tool)

P2073 (-)

1B

Engine 112, 113 as of 1/01

Fault code

( Display on generic scan tool)

P2073-[1] Short circuit to positive (-)

P2073-[2] Short circuit to ground(-)

P2073-[4] Interruption (-)

2

Fault storage

Activation of the engine diagnosis indicator lamp (EURO3/4)

or CHECK ENGINE (MIL) malfunction indicator lamp

After expiry of test duration and fault

No activation

3

Checking frequency

Continuous

4

Checked signal or status

PWM signal actuation and voltage supply for electric suction fan.

5

Fault setting conditions

Short circuit to positive

Short circuit to ground

Interruption

Fault if the duty cycle is greater than 90 %.

Fault if the duty cycle is lower than 10 %.

PWM signal actuation missing. Voltage supply (circuit 30) to electric suction fan interrupted.

6

Check prerequisites

Battery voltage between 8 and 17 V

7

In the event of a fault, the output stage is locked or switched for further troubleshooting. A short circuit to ground and a line interruption will be detected when the output stages are locked, whilst a short-circuit to positive is detected when the output stages are conducting.

- In the event of a fault in the actuation signal of the electrical suction fan, the fan is automatically switched to maximum speed.

The suction fan is actuated via the suction fan control unit or via integrated control at the suction fan.

Pay attention to the variant coding of the AAC or comfort AAC control and operating units.