ad0761p400056ba

Cylinder shutoff valve, ME-SFI fault code description

Typ ad · téma 07.61 · verze 0101 · 2005-08-18

Platí pro: ENGINE 113.960 as of 1.6.00 with CODE (479) Cylinder shutoff

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 07 Příprava směsi › 07.61 Systém vstřikování paliva a zapalování zážehového motoru ME

EinPAS 15 Motor › 15.45 Management motoru › 15.45.1 Základní informace

Platí také pro motory/převodovky: 113 960

AD07.61-P-4000-56BA

Cylinder shutoff valve, ME-SFI fault code description

Engine 113.960 from 6/00 with Code (479) Cylinder shutoff

Cylinder shutoff valve (Y80, Y81), electrical fault

1

Fault code

( Display on generic scan tool)

Cylinder shutoff valve, left cylinder bank (Y81) (-)

Cylinder shutoff valve, left cylinder bank (Y81) (-)

Cylinder shutoff valve, right cylinder bank (Y80) (-)

Cylinder shutoff valve, right cylinder bank (Y80) (-)

2

Fault storage

Activation of the engine diagnosis indicator lamp (EURO3/4)

After expiry of test duration and fault

No activation

3

Checking frequency

Continuous

4

Checked signal or status

Voltage supply for cylinder shutoff valve (output stage)

5

Fault setting conditions

Limit values

Short circuit to ground

Short-circuit to +12 V

Line interruption

Checking duration

Voltage lower than 2.5 V

Current higher than 4.2 A

No voltage at fuel injection valve and

approx. 4 to 8 V at output of ME-SFI control unit under no load.

approx. 1 seconds

6

Check prerequisites

Battery voltage 8 to 17 V

7

- Ensure the plug is fitted tightly at the cylinder shutoff valves.

- In the event of a short-circuit to +12 V, cylinder shutoff remains locked until the fault memory is cleared.

- In the event of a short-circuit to ground, the engine diagnosis malfunction indicator lamp is actuated immediately due to the simultaneous active fault detection of a "TWC-damaging" misfire.

- Actuation is checked for a line interruption and short-circuit (to ground or battery voltage). A short circuit to ground and a line interruption will be detected when the output stages are locked, while a short circuit to the battery voltage is detected when the output stages are conducting.

- The output stage is immediately no longer activated when a fault arises.