ad0761p400031a

Fault code description - ME-SFI - supply voltage and function of RPM sensors

Typ ad · téma 07.61 · verze 0104 · 2003-06-06

Platí pro: ENGINES 112.910, 112.911 up to 31.5.00, 112.920, 112.921 up to 31.5.00, 112.923, 112.940 /941 /942 up to 31.5.00, 112.943 ENGINES 113.940 /942 /943 up to 31.5.00, 113.961 ENGINES 112.945, 113.962 up to 30.11.00 in MODEL 463

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 07 Příprava směsi › 07.61 Systém vstřikování paliva a zapalování zážehového motoru ME — Řada 463

EinPAS 15 Motor › 15.45 Management motoru › 15.45.1 Základní informace — Řada 463

Platí také pro motory/převodovky: 112 910, 112 911, 112 920, 112 921, 112 923, 112 940, 112 941, 112 942, 112 943, 112 945, 113 940, 113 942, 113 943, 113 961, 113 962

AD07.61-P-4000-31A

Fault code description - ME-SFI - supply voltage and function of RPM sensors

1

Fault code

2

Fault storage

Activation of malfunction indicator lamp for engine diagnosis (EURO3/4)

or CHECK ENGINE (MIL)

after the end of the test period and faults

after two successive driving cycles with faults

3

Frequency of the test

continuous

4

Checked signal or status

- supply voltage for RPM sensors

- speed signal n2

- speed signal n3

5

Fault setting conditions

Supply voltage for RPM sensors

Lower limit

Upper limit

Speed signals n2, n3

Test duration

< 4.8 V

> 7.2 V

Signals detected and plausible

approx. 1 s

6

Test prerequisites for speed signal n2

Test prerequisites for speed signal n3

- engine speed > 450 rpm

- rear right wheel speed > 250 rpm

- rear left wheel speed > 250 rpm

- 3rd or 4th gear detected

- output shaft rotational speed > 180 rpm (> 20 km/h)

- no shift operation

7

Test sequence

Speed signals must be detected starting from a certain engine and wheel rotational speed.

The 3rd or 4th gear must also be engaged for speed signal n3.

8

Faults are detected by the ETC control module and sent via the CAN data bus to the ME-SFI control module. The faults are stored and the "CHECK ENGINE" malfunction indicator lamp (MIL) is activated by the ME-SFI control module.

Also read out ETC diagnostic trouble code memory, fault codes 11, 12, 13.