AD07.61-P-4000-22A | Regeneration monitoring pressure sensor ME-SFI fault code description | Model 129 up to 8/97 |
1 | Fault code | |
2 | Fault storage and activation of CHECK ENGINE (MIL) malfunction indicator lamp | following two successive journeys with faults |
3 | Checking frequency | once per journey |
4 | Checked signal or status | Regeneration monitoring pressure sensor signal (B4/4) |
5 | A Upper limit value Lower limit value Checking duration B Lower limit value Upper limit value Checking duration |
> 4.7 V (corresponds to approx. 35 mbar overpressure) < 0.1 V (corresponds to approx. 60 mbar vacuum) 10 s approx. 0.27 V approx. 4.9 V < 5 s |
6 | Check prerequisites | Blocking time after starting engine expired (approx. 10 s) |