ad0715g700106b

MR. (PLD) test of hydraulic system fuel return flow quantity

Typ ad · téma 07.15 · verze 0105 · 2012-01-18

Platí pro: ENGINE 900.91 /92, 902.92 /93, 904.92 /95, 906.935 /95, 924.91 /92 /93, 926.96

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 07 Příprava směsi › 07.15 Systém vstřikování paliva vznětového motoru (PLD), regulace motoru (MR) — Řada 900 (modely 91*, 92*) · Řada 902 (modely 92*, 93*) · Řada 904 (modely 92*, 95*) · Řada 906 (modely 935, 95*)

EinPAS 15 Motor › 15.45 Management motoru › 15.45.1 Základní informace — Řada 900 (modely 91*, 92*) · Řada 902 (modely 92*, 93*) · Řada 904 (modely 92*, 95*) · Řada 906 (modely 935, 95*)

Platí také pro motory/převodovky: 924 91*, 924 92*, 924 93*, 926 96*

AD07.15-G-7001-06B

MR. (PLD) test of hydraulic system fuel return flow quantity

Test procedure

Measuring instrument/test connection

Operation/

Preconditions

Specified value

Possible cause/

Remedy

1.0

Fuel return flow quantity

at outlet of fuel filter housing

Attach testing and measuring equipment to low-pressure fuel circuit

& (AR07.15-G-2000-01BC)

Engine: starting

Wait until fuel flows out practically free of bubbles at the measuring line

Idle speed:

Model 405.05

800 rpm

Model 405.10/12/20/22,

Model 437.42/43

720 rpm

Model 437.46

850 rpm

Measuring time > 1 minute

Maximum governed rpm:

2500 rpm

Measuring time > 30 s

Measuring point: Overflow valve

0.3 l/min.

0.3 l/min.

Fuel return flow quantity at overflow valve too low and within tolerance range at outlet of fuel filter housing

& (AD07.15-G-5001-08BA)

Fuel return flow quantity at overflow valve too low and too high at outlet of fuel filter housing

& (AD07.15-G-5001-08BB)

1.1

Fuel return flow quantity at overflow valve

Engine: starting

Idle speed:

Model 405.05

800 rpm

Model 405.10/12/20/22,

Model 437.42/43

720 rpm

Model 437.46

850 rpm

Measuring time > 1 minute

Maximum governed rpm:

2500 rpm

Measuring time > 30 s

0.9 up to
1.7 l/min.

2.7 up to
7.5 l/min.

Fuel return flow quantity at overflow valve within tolerance range and cannot be measured at outlet of fuel filter housing

& (AD07.15-G-5001-08BC)

Fuel return flow quantity at overflow valve and at outlet of fuel filter housing within tolerance range

& (AD07.15-G-5001-08BD)

Fuel return flow quantity at overflow valve too low and at outlet of fuel filter housing

& (AD07.15-G-7001-03B)