AD07.12-P-6000-17E | IFI test of electrical system electrohydraulic shut-off actuator | Testing coil |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Electrohydraulic shutoff actuator (Y1/1) Coil: Actuation |
18 | N3/7 |
43 | Engine: Idling |
11–14 V | IFI control module (N3/7) Y1/1 Cables 1.1 |
1.1 | Current consumption | N3/7 43 |
|
X4/30 | Ignition: OFF Disconnect coupling from IFI control module (N3/7) |
1.4–1.6 A Electrohydraulic shutoff actuator clicks audibly | Y1/1 Cables Control module box/engine separation point (X35/63) 1.2 |
1.2 | Resistance |
2 | Y1/11 |
3 | Ignition: OFF Disconnect coupling from electrohydraulic shutoff actuator (Y1/1) |
8.10.5 Ω | Y1/1 |