AD07.12-P-6000-16D | IFI test of electrical system EGR switchover valve |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | EGR switchover valve (Y27) (=Y31/1) Note on test connection: Insert pressure tester with Y-distributor arm between vacuum transducer (OUT) and EGR valve |
35 | N3/7 |
37 | Check vacuum at vacuum transducer OUT outlet Engine: Start 560-660 rpm 1500 rpm Blip throttle from 1500 rpm |
< 0.5 V < 100 mbar 11–14 V > 400 mbar Voltage and pressure drop | Y27 Check supply pressure Pressure lines Electric cables Vent filter contaminated f2 in K40/3 K40/3 IFI control module (N3/7) 1.1 |
1.1 | Current consumption |
18 | N3/7 |
35 | Ignition: ON | 0.8-1.2 A | Y27 1.2 |
1.2 | EGR valve leaktightness | Ignition: OFF Disconnect vacuum line and connect pressure tester. Pressurize EGR valve with 400 mbar | EGR valve closes audibly | EGR valve | |||