AD07.12-P-6000-10E | IFI test of electrical system fuel metering control | Testing adjustment solenoid |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Fuel quantity actuator (IFI) (Y23/1) Adjustment solenoid |
36 54 | N3/7 |
37 37 |
Ignition: ON |
> 4.0 V for max. 30 seconds | Y23/1 IFI control module (N3/7) Cables Connector Y23/1x1 1.1 |
1.2 | Coil resistance |
36 54 | N3/7 |
37 37 | Ignition: OFF Disconnect coupling from IFI control module (N3/7) |
1.2 Ω 0.2% 1.2 Ω 0.2% | Y23/1 Cables Connector Y23/1x1 |