ad0019n9026ba

Fault code list for seat electronics right (SIR) control unit

Typ ad · téma 00.19 · verze 0103 · 2008-01-15

Platí pro: MODEL 375.3 with BODY 375.810 MODEL 950.5 /6, 952.5 /6, 953.6, 954.5 with BODY 940.899

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 0 Celkový › 00 Celkové vozidlo › 00.19 Elektrická soustava vozidla, celkové propojení — Řada 375 (modely 3**, 810) · Řada 940 (modely 899) · Řada 950 (modely 5**, 6**) · Řada 952 (modely 5**, 6**) · Řada 953 (modely 6**) · Řada 954 (modely 5**)

EinPAS 37 Vnitřní výbava › 37.26 Sedadlo vpředu › 37.26.1 Základní informace — Řada 375 (modely 3**, 810) · Řada 940 (modely 899) · Řada 950 (modely 5**, 6**) · Řada 952 (modely 5**, 6**) · Řada 953 (modely 6**) · Řada 954 (modely 5**)

EinPAS 37 Vnitřní výbava › 37.27 Sedadlo vzadu › 37.27.1 Základní informace — Řada 375 (modely 3**, 810) · Řada 940 (modely 899) · Řada 950 (modely 5**, 6**) · Řada 952 (modely 5**, 6**) · Řada 953 (modely 6**) · Řada 954 (modely 5**)

AD00.19-N-9026BA

Fault code list for seat electronics right (SIR) control unit

11.1.08

MODEL 375.3 with BODY 375.810

MODEL 950.5 /6, 952.5 /6, 953.6, 954.5 with BODY 940.899

Fault code

Fault code description

0100

The supply voltage of the control unit is too high (overvoltage).

0101

The supply voltage of the control unit is too low (undervoltage).

0202

The supply voltage of the valves has Open circuit.

0203

The supply voltage of the valves has Short circuit.

0208

The supply voltage of the valves has external voltage.

0306

The feed air branch is faulty.

0406

The vent air branch is faulty.

1000

The potentiometer voltage 'height setting' is too high.

1001

The potentiometer voltage 'height setting' is too low.

1014

The 'Height setting' potentiometer voltage is faulty.

2002

The pushbutton operating unit has Open circuit.

2004

The pushbutton operating unit is operated continuously.

2005

The pushbutton operating unit is operated several times.

2007

The pushbutton operating unit has transmission fault.

2102

The memory module has Open circuit.

2104

The memory module is operated continuously.

2107

The memory module has a transmission fault.

4002

The deflate valve has Open circuit.

4003

The deflate valve has Short circuit.

4009

The 'deflate' solenoid valve has a short circuit or Open circuit.

4010

The 'deflate' valve is bridged with the 'inflate' valve.

4102

The 'inflate' valve has Open circuit.

4103

The 'inflate' valve has Short circuit.

4109

The 'inflate' solenoid valve has a short circuit or Open circuit.

4111

The 'inflate' valve is bridged with the 'deflate' valve.

4203

The 'moving height stop' valve has Short circuit.

4209

The 'moving height stop' solenoid valve has a short circuit or Open circuit.

4212

The 'moving height stop' valve is bridged with the 'off-road blocking' valve.

4303

The 'off-road blocking' valve has Short circuit.

4309

The 'off-road blocking' solenoid valve has a fault.

4313

The 'off-road blocking' valve is bridged with the 'moving height stop' valve.

7014

Internal control module error

7114

Ratio of minimum height to maximum height is incorrect.

7214

The specified height is incorrect.