AD00.19-N-9026BA | Fault code list for seat electronics right (SIR) control unit | 11.1.08 |
MODEL 375.3 with BODY 375.810
MODEL 950.5 /6, 952.5 /6, 953.6, 954.5 with BODY 940.899
Fault code | Fault code description |
0100 | The supply voltage of the control unit is too high (overvoltage). |
0101 | The supply voltage of the control unit is too low (undervoltage). |
0202 | The supply voltage of the valves has Open circuit. |
0203 | The supply voltage of the valves has Short circuit. |
0208 | The supply voltage of the valves has external voltage. |
0306 | The feed air branch is faulty. |
0406 | The vent air branch is faulty. |
1000 | The potentiometer voltage 'height setting' is too high. |
1001 | The potentiometer voltage 'height setting' is too low. |
1014 | The 'Height setting' potentiometer voltage is faulty. |
2002 | The pushbutton operating unit has Open circuit. |
2004 | The pushbutton operating unit is operated continuously. |
2005 | The pushbutton operating unit is operated several times. |
2007 | The pushbutton operating unit has transmission fault. |
2102 | The memory module has Open circuit. |
2104 | The memory module is operated continuously. |
2107 | The memory module has a transmission fault. |
4002 | The deflate valve has Open circuit. |
4003 | The deflate valve has Short circuit. |
4009 | The 'deflate' solenoid valve has a short circuit or Open circuit. |
4010 | The 'deflate' valve is bridged with the 'inflate' valve. |
4102 | The 'inflate' valve has Open circuit. |
4103 | The 'inflate' valve has Short circuit. |
4109 | The 'inflate' solenoid valve has a short circuit or Open circuit. |
4111 | The 'inflate' valve is bridged with the 'deflate' valve. |
4203 | The 'moving height stop' valve has Short circuit. |
4209 | The 'moving height stop' solenoid valve has a short circuit or Open circuit. |
4212 | The 'moving height stop' valve is bridged with the 'off-road blocking' valve. |
4303 | The 'off-road blocking' valve has Short circuit. |
4309 | The 'off-road blocking' solenoid valve has a fault. |
4313 | The 'off-road blocking' valve is bridged with the 'moving height stop' valve. |
7014 | Internal control module error |
7114 | Ratio of minimum height to maximum height is incorrect. |
7214 | The specified height is incorrect. |