AD00.19-N-9008EA | Fault code list for flame starting system (FLA) control unit | 11.1.08 |
MODEL 374.5 /6, 375.3 /4, 940, 942, 943, 944
MODEL 950.5 /6, 952.5 /6, 953.6, 954.5 with BODY 940.890
MODEL 958.2 /4
Fault code | Fault code description |
0100 | The supply voltage of the control unit is too low (undervoltage). |
0101 | The supply voltage of the control unit is too high (overvoltage). |
0202 | Flame glow plug has Open circuit. |
0203 | Flame glow plug has Short circuit to ground. |
0204 | Flame glow plug has Short circuit to positive. |
0206 | Glow plug voltage difference |
0302 | Solenoid valve LOW has Open circuit. |
0303 | Solenoid valve LOW has Short circuit to ground. |
0304 | Solenoid valve LOW has Short circuit to positive. |
0305 | Solenoid valve LOW overload |
0310 | Solenoid valve LOW continuously actuated |
0402 | Solenoid valve 2 has Open circuit. |
0403 | Solenoid valve 2 has Short circuit to ground. |
0404 | Solenoid valve 2 has Short circuit to positive. |
0405 | Solenoid valve 2 overload |
0410 | Solenoid valve 2 continuously actuated |
0503 | Solenoid valve HIGH has Short circuit to ground. |
0504 | Solenoid valve HIGH has Short circuit to positive. |
0604 | Preglow indication Short circuit to positive |
0706 | Control unit FLA flame starting system detects difference in voltage between glow plug and control unit. |
0707 | CAN bus-fault |
0708 | Internal fault in control unit |
0709 | Internal fault in control unit |
0712 | Control module is not parameterized. |
0811 | Boost air temperature exceeded |